SmartView 180 (SV180) 180mm Paperless Data Acquisition System Download printable brochure
The Thermo Scientific SV180 provides an innovative approach to streamlining the collection, distribution and analysis of critical process data replacing existing paperless or traditional chart recorders.
Engineered to meet today's sophisticated data management requirements, the SV180 couples intuitive touchscreen technology with a networkable platform to provide an integrated and scalable data acquisition and management solution. When compared to systems with similar form factor, engineers and operators will appreciate the brilliant 12.1 in. display, increased input/output handling and communications capabilities as well as the flexible data storage
options. All hardware is accessible from the front panel making it easy to expand as your needs evolve.
Details:
- Up to 80 universal input channels
- All points scanned once a second
- Wide variety of user-selectable display modes
- Redundant storage media capability
- RS-232 and RS-485: Modbus, ASCII
- Ethernet communication (10 Base-T): TCP/IP, ModEthernet, FTP
- ProView Software Suite for remote configuration, historical data analysis and/or real-time viewing
- Parallel printer port and VGA video output port (800 x 600)
Compliance: OPC and PI compliant
|
Specifications
|
|
Inputs
|
|
Number
|
16, 32, 48, 64 and/or 80 isolated direct inputs plus additional 80 calculated channels
|
|
Type
|
DC Voltage: Linear and square root programmable to 10 VDC (50 mV, 100 mV, 200 mV, 1 V, 5 V and 10 V bipolar ranges)
DC Current: Linear, square root and log programmable to 4-20 mA, 10-50 mA and dry contact
T/C: J, K, T, E, R, S, B, C, Nicrosil Nisil and Nickel/Nickel Moly
RTD: 10W Cu, 100W Pt 385, 100W Pt 392, 200W Pt 385, 200W Pt 392 and 120W Ni
External: SM100, DCS, PLC, SCADA or computer generated
|
|
Accuracy
|
Voltage: ±0.05% of programmed range; Current: ±0.1% using external shunt resistor
T/C: ±1°C for J, K, T, E, Nicrosil-Nisil and Nickel/Nickel Moly; ±3°C for R, S, and C; ±4°C for B; RTD: ±0.5°C
|
|
Resolution
|
0.006% of full scale
|
|
Impedance
|
>10 MW
|
|
Common Mode Voltage
|
300 VAC p-p
|
|
Normal Mode Noise Rejection
|
60 dB at 50/60 Hz
|
|
Scan Rates
|
All points scanned once a second
|
|
Recording
|
|
Range
|
User programmable 1 sec to 24 hours
|
|
Format
|
ASCII or Binary
|
|
Internal Memory
|
64 MB RAM, 500 KB non-volatile RAM, 8 MB Flash
|
|
Storage Media
|
1.44 MB (3.5-in) floppy disk, Type II PC card ATA Flash and/or Compact Flash with adapter
|
|
Data Storage Methods
|
Data may be saved to storage media as instantaneous, average, max or min values
Data may be saved based on user-defined interval, alarm or external trigger
|
|
File Type
|
Data file, alarm/event file, configuration file
|
|
Display
|
|
Type
|
12.1 in. color active matrix TFT touchscreen LCD (800 x 600)
|
|
Display Modes
|
Up to 9 user-defined screens (vertical trend, horizontal trend, vertical bargraph, horizontal bargraph, digital, overview, alarm/event, circular and four-quadrant split); up to 32 points per trend screen; 1 user defined quadrant screen
|
|
Display Colors
|
Up to 40 colors
|
|
Virtual Chart Speed
|
User programmable in mm or inches per hour
|
|
Virtual Chart Scales
|
User programmable
|
|
Video Output
|
External VGA port (VGA 800x600)
|
|
Alarm Functions
|
|
Number of Alarms
|
Up to 5 alarm setpoints per point
|
|
Alarm Types
|
High, low, rate of change and abnormal
|
|
Contact Output/Input
|
16 isolated Form A or B contact outputs and 12 digital inputs per card (1 Amp @ 117 VAC or 26 VDC resistive,
0.5 Amp @ 230 VAC resistive, 0.4 Amp @ 250 VDC resistive); up to 5 input/output cards
1 common alarm (100 mA @ 250 VDC/VAC)
|
|
Deadband/Failsafe
|
User selectable
|
|
Power
|
|
Requirements
|
90-132/180-264 VAC (50 to 60 Hz)
|
|
Consumption
|
120 VA max (powering 80 transmitters); 40 VA (no transmitter powered)
|
|
Power Fail Protection
|
Programmed parameters stored in nonvolatile memory; clock battery
|
|
Transmitter Power Supply
|
24 VDC at 2 Amps (60 VA or 120 VA maximum with option)
|
|