ETA Process Instrumentation - since 1971

ETA Process Instrumentation -- Since 1971

ETA Associates merged with Process Instrumentation Inc. as of 9/1/2011. Visit our sister companies: Safety Inc and iFacility Service.

     Home

  Manufacturers 

Industries & Instruments

Technical Resources

    Service   

     About      

Thermo Texas Nuclear Kay Ray Sensall

 


 

Thermo Process Monitoring and Industrial Instruments

Flow, Density and Level Measurement - Continuous, Point and Tilt Level Measurement

Continuous, point, sonic and tilt level measurement controllers. Increase process efficiency, run a safer system, produce higher quality products and improve your bottom line.

 Thermo PNF Point LevelSwitch

Thermo Scientific PNF Point Level Measurement System                                      Download printable brochure.

Thermo Scientific PNF Point level switch is a non-contacting, non-invasive point level switch for high or low level indication.
Highly reliable, rugged and provides cost-effective on-off control of circuits. Mounted externally on tanks, bins, hoppers, pipes, chutes or other vessels to sense the level of liquids, slurries, and solids. Consists of two components: an energy source in a steel-jacketed housing and the detector/electronics. It operates on the principle of gamma ray attenuation.
 
Details:
  • Digital technology
  • Simple installation and easy setup
  • CSA-US approved for hazardous areas
  • Unaffected by process variables such as presure, temperature, viscosity or density
  • CSA-US approved

Warranty and Service Offering: Two years

Certifications: Canadian Standards Association: Carbon or stainless-steel detector: Class I, Div. 1, Groups B, C & D; Class II, Div. 1, Groups E, F & G; (CSA/US) Class III, Div. 1, ENCL Type 4
 
 

Specifications

 

Performance Specifications

Precision ±6mm (±0.25 in.); Exact value depends upon requirements of specific application
Size of Vessel Installs on vessels that measure from 2 in. (51mm) to 300 ft. (91.4m) in diameter

Maximum diameter depends upon thickness of the wall vessel
Sampling Time 0.13 to 204 seconds, depending on application
Response Time Approx. 1.5X sampling time
Radiation Field Required 0.05mR/hr. or greater, depending on sampling time
Radiation Change 25% minimum radiation change required for operation
Ambient Temperature Field Standard: -40° to +94°C (-40° to +200°F); Optional water-cooled housing available for high temperature applications
Surface Radiation Dependent on the application, source selection and physical installation
Power 115VAC ±10% @ 10VA, 50 to 60Hz; Optional 230VAC @ 10VA
Power Supply Effect No effect on operation over specified power supply ranges
 

Gamma Ray Source

Source Type Cs-137 or Co-60, both stainless steel, doubly encapsulated
Source Size Cs-137: 10 to 10,000 mCi; Co-60: 1000 to 5000 mCi; Source size dependent on application
Source Housing Carbon steel, lead filled, polyurethane painted; Stainless-steel; Water-cooled option available; Two position shutter, locks in Off (closed) position
  Functional Specifications: Transmitter/Detector
Detector Type Detector Type: Halogen-quenched Geiger-Mueller tube
Programming Factory calibrated
Operating Temperature Range Process: unlimited; Detector: -40° to +93°C (-40° to +200°F) ambient
Storage Temperature Limits -30° to +65°C (-22° to +149°F)
Current Outputs Hermetically sealed at 115VAC at 5A or 230VAC at 5A
Contact Closure Outputs 110 to 220VAC/28VDC ±10% SPDT at 5A; Hermetically sealed relays
Circuitry Digital; Fully integrated
Failsafe Choice of either high level or low level failsafe operation
Physical Specifications
Electrical Connections One 3/4 in. NPT fitting
Interface Cable Any wire capable of 5A at 115/230VAC
Mounting Hardware Detector: NEMA4 and XP housings available; Anti-shock mount available
Housing Detector: Carbon steel, polyurethane painted; Optional 316 stainless-steel; Optional water-cooled detector for high temperature applications; Optional detector housing: aluminum construction
Size Optional aluminum detector housing: 11.12L x 6H x 6 in.D (283 x 152 x 152mm)
Weight, Detector/Electronics Optional aluminum detector housing: 4.5 lb. (2kg)
 

Home - Thermo Thermo Brandt - Thermo Sarasota - Thermo Texas Nuclear Kay/Ray Sensall - Thermo Westronics 

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 