Specifications
|
|
Performance Specifications
|
|
Precision
|
0.5% of span typical
|
|
Stability
|
0.5% of span typical
|
|
Response Time
|
1 to 1054 seconds
|
|
Radiation Field Required
|
Application dependent; consult Thermo Fisher Scientific
|
|
Ambient Temperature Field
|
Standard: -40°C to +60°C (-40°F to +140°F)
|
|
Surface Radiation
|
Dependent on the application, source selection and physical installation
|
|
Power
|
115 or 230VAC ±10%, 50 to 60Hz or 24VDC available; Surge protected to 9 to 35VDC
|
|
Power Supply Effect
|
No effect on operation over specified power supply ranges
|
|
Gamma Ray Source
|
|
Source Type
|
Cs-137 or Co-60, both stainless steel, doubly encapsulated
|
|
Source Size
|
Cs-137: 10 to 10,000 mCi; Co-60: 1000 to 3000 mCi; Source size dependent on application
|
|
Source Housing
|
Carbon steel, lead filled, polyurethane painted; Stainless steel; Water-cooled option available in both carbon and stainless steel; Two position shutter, locks in Off (closed) position
|
|
Functional Specifications: Transmitter/Detector
|
|
Detector Type
|
PVT plastic scintillator with wide dynamic range; PVT resists shock and moisture damage
|
|
System Architecture
|
Multiprocessor-based electronics provide uninterrupted output during data entry and system interrogation
Surface-mounted technology provides high degree of reliability; All user data doubly stored in non-volatile memory with no battery backup required
|
|
Software
|
Comm PC Interface Software: Interface with up to 32 LevelPRO units over RS485 loop (RS485 to RS232 converter provided)
|
|
Programming
|
HART Smart Model 275/375/475 Handheld Terminal: used to setup and calibrate gauge, and to enter data
Communicates with any LevelPRO via the current loop; BEL202FSK standard
Thermo Scientific 9734 Handheld Terminal: used to setup and calibrate gauge, and to enter data; Communicates with any LevelPRO via the RS485; connector provides upload/download of gauge configuration to/from PC via RS232 interface Foundation Fieldbus
|
|
Operating Temperature Range
|
-40°C to +60|C (-40°F to +140°F) ambient
|
|
Storage Temperature Limits
|
-30°C to +65°C (-22°F to +149°F)
|
|
Inputs
|
Signal from another LevelPRO detector; Additional input for gas density compensation or buildup available
Dry contact closure
|
|
Current Outputs
|
4 to 20mA isolated loop-powered into 800ohm, field scalable; 4 to 20mA isolated self-powered into 800ohm, field scalable
|
|
Serial Outputs
|
RS485 half duplex; RS232 full duplex
|
|
Contact Closure Inputs
|
2X programmable dry contact inputs
|
|
Contact Closure Outputs
|
Two 115VAC/28VDC SPDT @ 10A (230VAC SPDT @ 8A)
|
|
Source Decay Compensation
|
Selectable Cs-137, Co-60 or Am-241
|
|
Linearization
|
Logarithmic and multipoint characterization
|
|
Analog Output Adjustment
|
Engineering units and range values user-selected; All analog trim and adjustments made through software commands
|
|
Circuitry
|
Digital; Fully integrated
|
|
Physical Specifications
|
|
Electrical Connections
|
Two 3/4 in. NPT fittings; HART Communicator interface connects directly into 4 to 20mA loop
|
|
Interface Cable
|
Shielded 14 to 22 gauge Belden 9318
|
|
Transmitter Display
|
Thermo Scientific Model 9723: two line, 16 alphanumeric character, backlit LCD; Powered from electronics
Maximum separation from electronics 91.4m (300 ft.)
|
|
Mounting Hardware
|
Integrated transmitter/detector: integral bolt-on bracket; Gamma ray source: integral bolt-on bracket
|
|
Housing
|
Detector: Carbon steel, polyurethane painted; Optional 316 stainless steel; Optional water-cooled detector for high temperature applications
|
|
Size
|
Standard detector lengths are in 1 ft. increments from 1 to 12 ft. (0.3m to 3.6m);
Multiple detectors can be wired together for large measurement spans (unlimited in number)
|
|
Weight, Detector/Electronics
|
Size dependent; consult Thermo Fisher
|