Ametek Western Research Western Research

Although Western Research is best known as the world leader in providing analyzers for the sulfur recovery industry, their photometric and spectrophotometric process analyzers are used in wide variety of industries worldwide for reaction monitoring and control, emissions monitoring, feedstock monitoring, and product quality assurance. They produce a carefully engineered selection of single wavelength, multi-wavelength, and broad spectral analysis instruments for rack mount and industrial field installation. These instruments can be adapted to a tremendous variety of applications and end uses.

Western Research
A wide range of standard and custom-built industrial UV-Vis photometric analyzers for various chemical composition analyses of inert, reactive, and toxic gases or liquids. Used to monitor or control: feedstock quality, reaction rates, quality control/assurance, blending analysis, pollutants, etc.

Ametek Western Research Model 9000RM Gas Analyzer 

Model 9000RM Gas Analyzer                         Download printable brochure.

NEW GENERATION! REPLACES MODELS 921 AND 922.

The AMETEK Model 9000RM is a rugged single or multi-component gas analyzer housed in a single 19-inch, rack-mountable unit that can be integrated into Continuous Emission Monitor Systems (CEM) or used alone for a variety of gas monitoring applications.

The Model 9000RM can be configured to measure most gas species that absorb in the UV (examples NOx, H2S and SO2). The optional low range white cell provides longer path length for measuring lower concentrations. For example, the minimum full scale for SO2 is 25 ppm, with an accuracy of 1% of full scale.

Resolution better than 0.02 nm is provided by high intensity, line source lamps. These sources emit at a fixed wavelength, providing great measurement stability, and emit low total power, removing the potential for sample photolysis. The high resolution enables unparalleled linearity over a wide dynamic range (less than 1% deviation over 4 to 5 orders of magnitude) which, in turn, leads to simple, robust data analysis.

 
Specifications

Species Measured

Single Species
Minimum Full Scale

Multi-Species
Minimum Full Scale

SO2

25 ppm

50 ppm

H2S

50 ppm

100 ppm

NO

50 ppm

200 ppm*

NO2

100 ppm

200 ppm*

NOx

n/a

200 ppm*

* Lower ranges available upon request

Maximum full scale on all systems: 100%
Methodology: Multiple wavelength, high resolution, non-dispersive ultraviolet
Optional O2: Integral paramagnetic sensor
Accuracy: Better than 1.0% of standard full scale range O2 : ¡¾0.1%
Repeatability: ¡¾0.5% full-scale of standard ranges O2 : ¡¾0.2% (reading varies by 0.05% due to A/D resolution)
Linearity: SO2: < ¡¾1.0% full scale
NO, NO2, NOx, H2S: < ¡¾1.5% full scale
O2: ¡¾0.1%
Response Time: 90% in 30 seconds or less
Number of Gases: 1 (single species version)
Up to 5 (multi-species version)
Typical Sample Flow: 0.25 - 5 l/min (0.6 - 10.5 SCFH)
Sample Gas Requirements: Noncorrosive, non-condensing, free from oil and with less than three micron particulates (0-95%, non-condensing)
Sample System Limits: 5 psig max (without the dynamic pressure compensation option, the reported concentrations will be directly proportional to barometric pressure)
Pressure and Temperature Compensation: Optional
Ambient Conditions
  Storage: -40 to 70¢ªC (-40 to 158¢ªF)
  Operating: -20 to 50¢ªC (-4 to 122¢ªF) without Paramagnetic O2 sensor, 0 to 50¢ªC (32 to 122¢ªF) with Paramagnetic O2 sensor 0.95 Relative Humidity
Zero Drift: Typically better than 2% full scale standard ranges in 24 hours
Utility Requirements
  Electrical: 120 VAC (105 to 132 VAC), 47 to 63 Hz
240 VAC (209 to 264 VAC), 47 to 63 Hz
  Power Consumption: < 300 W maximum start-up (from a cold start) with average power dependant on ambient temperature
Outputs: Two (expandable to six) isolated Analog Outputs, each configurable to 0-20 mA, 4-20 mA, 0-5V DC
Four (expandable to six) Relay Contacts, Contact Form A (SPST), normally open. Switching: maximum 240 V DC, 0.5 A DC, limited to 10 W.
Carry: maximum 1.2 A DC Four optional solenoid drivers 24 V DC 0.5A max.
Inputs: Two optional isolated analog inputs, each configurable to 0-5 Volts or 0-20 mA.
Two (expandable to four) contact inputs, each pair isolated from analyzer. Voltage 5 V DC unregulated.
Current approx. 7 mA.
Communications: Modbus RTU RS485 and Modbus TCP
Fast Ethernet - network connection or web-based server
Physical Dimensions
(W x H x D):
48.2 cm x 17.7 cm x 60.256 cm
(19 in. x 7 in. x 23.7 in.)
Weight: 18.2 kg (40 lb)
 
Ametek Main Page - Ametek Thermox Analyzers - Dycor Quadropole Mass Spectrometers - Process Moisture Analyzers - Oxygen Analyzers - Ametek Land

 

4 G Technologies • Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes OptechPercival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 