ETA Process Instrumentation - since 1971

ETA Process Instrumentation -- Since 1971

ETA Associates merged with Process Instrumentation Inc. as of 9/1/2011. Visit our sister companies: Safety Inc and iFacility Service.

     Home

  Manufacturers 

Industries & Instruments

Technical Resources

    Service   

     About      

Ametek Thermox Ametek Thermox

 Thermox analyzers from Ametek are among the most established combustion monitoring and control devices available today. A broad range of products is available for analyzing oxygen, combustibles, and methane in combustion flue gases for combustion control, safety, and thermal NOx reduction. Industries served include Electric Power Generation, Petroleum Refining, Petrochemical Processing, Cement & Lime Manufacturing, Glass and Ceramics, Pulp & Paper, Iron & Steel, and Non-Ferrous Metals production.  
Ametek Insitu Replacement Probe 

Insitu Replacement Probes             Download printable brochure.

The Need
Removing an oxygen insitu probe from any combustion process is a time consuming and costly task. Periodic removal of insitu probes is required to protect zirconium oxide cells from chemical washdown operations while higher blends and increased use of high ash and lower sulfur PRB coals require more frequent removal of probes to clean plugged filters.

The Solution
All WDG-Insitu flue gas oxygen probes incorporate the unique inner/outer probe design which facilitates removal of the cell/heater assembly through the probe head. Once the inner probe is removed, the outer probe support pipe allows straight run access to insitu filter for cleaning with compressed air. This feature significantly reduces turn-around time. The WDG-Insitu probe is compatible with existing Yokogawa, Westinghouse/Enotec, and Rosemount WC3000 discrete microprocessor controls so entire replacement of oxygen system is not required to obtain this maintenance cost reduction feature.

  Insitu Replacement Probes
Over the past five years Thermox has been replacing Westinghouse/ Hagan, or Rosemount WC3000 probes, utilizing the existing electronics with the WDG-Insitu. The WC3000 control electronics require no software or wiring interconnection configuration changes. The Thermox probe is easily retrofitted to work with the Westinghouse 218A controller with only a minor change.

Thermox replacement probes for Westinghouse/Hagan or Rosemount WC3000 and Yokogawa ZO21-D-L are available in 0.5’ (.228 m), 1.5’ (.457 m), 3’ (.914 m), 6’ (1.83 m) and 9’ (2.74 m) lengths. Each probe is provided with a 2” MNPT connection flange. 
 
 

Ametek Main Page Thermox - Western Research - Process Instruments - Dycor - Land - Chandler - Trace Analytical

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 

ETA Process Instrumentation, 119 Foster Street, Bldg. 6, Peabody, MA 01960 • (978) 532-1330 or sales(a)etapii.com