ETA Process Instrumentation - since 1971

ETA Process Instrumentation -- Since 1971

ETA Associates merged with Process Instrumentation Inc. as of 9/1/2011. Visit our sister companies: Safety Inc and iFacility Service.

     Home

  Manufacturers 

Industries & Instruments

Technical Resources

    Service   

     About      

Ametek Thermox Ametek Process Instrumentation
 

AMETEK offers on-line process analyzers for the accurate determination of the trace moisture content of gases. Analysis ranges and accuracy vary by model from as high as 2500 parts per million by volume down to <1 part per billion by volume.  In addition, AMETEK provides a line of products based on tunable diode laser technology.

Ametek Process Instruments Model 5000 Process Moisture Analyzer 

Model 5000 Process Moisture Analyzer                  Download printable brochures: 5000 Moisture Analyzer - Sample System - 5000 Controller

The versatile AMETEK Model 5000 is a highly sensitive moisture analyzer for process applications where the continuous, reliable measurement of moisture in vapors and gases is required.
The Model 5000 analyzer measures moisture on-line by monitoring the vibrational frequency change of a hygroscopically sensitized quartz crystal that is exposed alternately to wet sample and dry reference gas for 30 second periods. The reference gas is sample gas passed through a molecular sieve dryer to remove virtually all its moisture content.

TYPICAL APPLICATIONS

Catalytic Reforming

Problem - Proper moisture balance in feedstocks and hydrogen recycle streams must be maintained to optimize product yield and catalyst life. Measurement reliability is greatly complicated by the presence of compressor oils and high boiling point hydrocarbons in the stream. The reformer process typically requires accurate and rapid results despite variations in moisture content from 10 to 25 parts per million.

Solution and Results -  The  Model 5000's accuracy, reliability, and fast response are not affected by normal reformer contaminants such as compressor oils and high boiling point hydrocarbons. The on-board moisture generator verifies measurement accuracy for optimum product yield. Readings are absolute and provable, not just trends.

Moisture in Olefins

Problem - Ethylene polymerization catalysts are extremely sensitive to trace water. Water decreases catalyst activity and may turn the catalyst black, leading to discoloration of the virgin polymer. Accurate, reliable, and rapid sub-1 ppm moisture analysis is required.

Solution and Results - The Model 5000's quartz-crystal sensor does not promote unsaturated hydrocarbon polymerization, a common problem with electrolytic moisture sensors. Exceptional response speed and precision in the sub-1 ppm moisture range ensures consistently high product quality. The on-board moisture generator verifies this measurement accuracy.

Moisture in Natural Gas 

Problem - Excess moisture in natural gas causes serious problems, from pipeline, storage tank, and equipment corrosion to gas hydrate formation. Measuring moisture in natural gas is not a difficult application, but reliably measuring it on a continuous basis is. Glycol carryover and entrained compressor oils can quickly damage insitu sensors.

Solution and Results - The extended cell life mode minimizes sensor exposure to contaminants and strips volatile contaminants. The on-board moisture generator permits you to quickly and easily verify and adjust calibration.

OTHER APPLICATIONS

The 5000 provides similar solutions to problems in a variety of other applications, including:

  • Petroleum Refining - reforming; alkylation; LPG; light hydrocarbons; isomerization       
  • Natural Gas - cryogenic extraction; transmission stations; storage/distribution; LNG; production       
  • Petrochemicals - cracked gas; propylene; butadiene; ethylene       
  • Chemicals - fluorocarbon gases; vinyl chloride; vinyl fluoride; refrigerants; reactor gas blankets; methyl chloride       
  • Enhanced Oil Recovery - CO2 pipelines       
  • Electronics - doping gases; dielectric gases; soldering furnace atmospheres; brazing furnace atmospheres; blanketing gases       
  • Metals - annealing furnace atmospheres
 
Model 5000 Specifications
Ranges: Calibrated 0 to 1000 ppm by volume (ppmv). Display c ontinues to provide trend information above 1000 ppmv. Output capability in lb/mmscf and dewpoitn (requires sample line pressure as analog input; single point systems only) 
Outputs:  80-character vacuum fluorescent display. Two 4-to-20 mA analog signals with completely user-settable span; one analog output is autoranging. RS485 bidirectional serial port
Alarms (3):  System alarm; Concentration alert; Range or calibration alert
Sensitivity:  0.1 ppmv or 0.5% of reading, whichever is greater
Accuracy:  0 to 20 ppm; 1 ppm; greater than 20 ppm; 5% of reading
Reproducibility:  0.2 ppmv or 1% of reading, whichever is greater
Operating Pressure:  103 kPa (15 psi) gauge. Allowable Inlet Pressure: 207 to 690 kPa (30 to 100 psi) gauge
Sample Gas Temperature:  0º to 100ºC (32º to 212ºF) 
Gas Flow Requirements: All systems are available with choice of nominal AC voltages
  100± 10%, 50/60 Hz
  115± 10%, 50/60 Hz
  230± 10%, 50/60 Hz
  Field Unit: 175W
  Controler: 95-230 V ± 10%, 47-63 Hz, 75W
Maximum Separation: 600m (2000 ft.) between field unit and controller
Ambient Temperature Limits: Field unit: -20º to 50ºC (-4º to 122ºF) without heat; -40º to 50ºC (-8º to 122ºF) with optional electric heat
Controller: -10º to 50ºC (14º to 122ºF)
Moisture Generator Value: Exact values stated with analyzer; Nominal: 20 ppmv; Low option: 3 ppmv
 
Ametek Main Page - Back to Ametek Process Instruments Page
Thermox - Western ResearchLand - Dycor - Chandler - Trace Analytical


 

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 

ETA Process Instrumentation, 119 Foster Street, Bldg. 6, Peabody, MA 01960 • (978) 532-1330 or sales(a)etapii.com
Privacy PolicyTrade Mark StatementContact UsWebmail Login