 Perma Pure products, baldwin and Nafion can be purchased at ETA Associates (978) 532-1330 Perma Pure LLC - The leader in Gas Conditioning

Perma Pure Direct Extractive Filter Probes

Baldwin's Direct Extractive Filter Probes feature an advanced design to extract sample gas and remove particulate while preventing condensation prior to the gas sample entering the heated sample line.

 Baldwin General Purpose Probe General Purpose Probes

Baldwin's new Sure-Lock filter assembly is precision machined and features a unique design to help ensure proper insertion into the assembly and to reduce the possibility of leaks. The filter head is inserted into a notch in the assembly to ensure proper alignment before locking it in place. The o-rings are tightened under compression, rather than being located on the sides of the filter head, to reduce the risk of leakage. Download brochure.
  • Sure Lock™ filter assembly reduces risk of leakage
  • Broad range of filter elements designed for various applications
  • Insulated enclosure with heat-shrink sample line boot to maintain constant temperature
  • Available with air blowback system
Options Available:
  • Schedule 40, Schedule 80, Hastelloy, and Durinert+ stinger probes
  • Sintered stainless steel, screen mesh, ceramic, glass fiber, and Hastelloy filter elements
  • Air blowback system with 115 VAC, 230 VAC, 12 VDC, or 24 VDC solenoid
  • Solenoid to close sample line when blowback is initiated
  • Gas cooling spool piece for high temperature gas sources
  • Eliminates the complexity of separate temperature controllers heater bands and Kalrez o-rings for high temperature sampling requirements
  • Various size flanges
  • Durinert® or Teflon coated filter assembly option for corrosive gas streams
Model Blowback Filter Assembly
Temp Control
Temp/Blowback
Circuit Board
Enclosure Dimensions*
HWD
Weight
31  N/A  Self
Regulated
N/A  Insulated
Canister
6x14x6 in
15x36x15 cm
14 lbs
6 kg
 
32C   N/A External Regulated N/A NEMA 4
Steel
14x12x8 in
36x30x20 cm
30 lbs
14 kg
 
33C N/A Self
Regulated
N/A NEMA 4
Steel 
14x12x8 in
36x30x20 cm 
30 lbs
14 kg
34C  2-way
solenoid
External Regulated N/A NEMA 4
Steel
14x12x8 in
36x30x20 cm 
34 lbs
15 kg
34C-R  2-way
solenoid 
Self
Regulated
N/A NEMA 4
Steel
14x12x8 in
36x30x20 cm
34 lbs
15 kg
 
 35C 2-way
solenoid 
Circuit Board Regulated Integral NEMA 4
Steel
14x15x8 in
36x38x20 cm
37 lbs
17 kg
36C 4-way
solenoid
Circuit Board Regulated Integral NEMA 4
Steel
14x15x8 in
36x38x20 cm 
37 lbs
17 kg

 

 

 

 

 

 

 

Download printable brochures:   31       32C        33C        34C & 34C-R         35C           36C

 Baldwin Hazardous Probe

Hazardous Area Probes
Baldwin's Direct Extractive Filter Probes feature an advanced design to extract sample gas and remove particulate while preventing condensation prior to the gas sample entering the heated sample line. Download brochure
  • Available for Class 1 Division 2 and Class 1 Division 1 applications
  • Sure-lock filter reduces risk of leakage
  • Range of filter elements designed for various applications
  • Available with air blowback system
Model

Area
Classification

Blowback

Filter
Assembly
Temp Control

Enclosure

Dimensions* HWD

 Weight

34 C-Z

Class 1, Div 2
Groups B,C,D

2-way
solenoid

External Regulated

NEMA 4X
306 stainless steel

14x20x8 in
36x51x20 cm

40 lbs
18 kg

34 C-R-Z

Class 1, Div 2
Groups B,C,D

2-way
solenoid

Self Regulated

NEMA 4X
306 stainless steel

14x20x8 in
36x51x20 cm

40 lbs
18 kg

33 XP

Class 1, Div 1
Groups B,C,D

N/A

Self Regulated

UL® Classified Aluminum

8x8x11 in
20x20x28 cm

30 lbs
14 kg

34 XP

Class 1, Div 1
Groups B,C,D

2-way
solenoid

Self Regulated

UL® Classified Aluminum

8x8x11 in
20x20x28 cm

33 lbs
15 kg

Download brochures: 34C-Z & 34C-R-Z        33XP         34XP

 Permapure Baldwin Model 45 Dilution Probes
Baldwin™ - Series Model 45
Dilution Extraction Probes Eliminate Conditioning Systems & Heated Lines
Baldwin™ -Series Model 45 Dilution Probe conditioning systems from Perma Pure draw, filter and dilute sample gases in preparation for analysis. The out-of-stack conditioning system dilutes the sample gas 10 to 250 times with dry air, reducing the water vapor content and eliminating high-cost heated lines. Download brochure.
  • Selectable dilution ratios
  • Dilution air pre-heater
  • Optional fast loop bypass
  • Plug-free operation
  • Self-regulating temperature
  • Wet basis measurement
 

 

www.permapure.com
For more information, contact us at:
Tel: (978) 532-1330 or Email at eta@etaassociates.com 

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 

ETA Process Instrumentation, 119 Foster Street, Bldg. 6, Peabody, MA 01960 • (978) 532-1330 or sales(a)etapii.com
Privacy PolicyTrade Mark StatementContact UsWebmail Login